EasyChem Plus

Fully automated analyzer based on Discrete analysis technology, with 60 positions samples tray including blank, controls and calibrants cups.

  • 60 sample tray capability including blanks, standards and controls;

  • Up to 18 reagents in a temperature controlled tray;
  • 96 reaction cuvettes temperature controlled;
  • Colorimeter with a computer controlled filter wheel, for automatic wavelength selection;
  • Standard flow cell 10 mm, 20 mm or 50 mm pathlength (sea water version);
  • Auto Pre run sample dilution;
  • Auto sample dilution for off scale samples;
  • On line QC and QC database including QC chart;
  • Throughput: 60 test for hour;
  • Cd coil reduction option for Nitrate.

Easy Operation

Simply load the sample tray, select the tests to be performed, and click start. It’s that simple!

No prior training or experience required, the Windows based software is easy to use and learn.

Reduce labor costs and increase productivity, the automated design allows technicians to perform other tasks.

Calibration

Calibrations curves can be generated from a prepared standard. The EasyChem Plus can auto-dilute based on a preprogrammed concentration to ensure your ​results. All calibration information is automatically saved for traceability and can be exported into reports for auditing purposes.

Reagents

The EasyChem Plus has up to 18 reagent positions.

The reagent tray is refrigerated to extend the life of the reagents.

Each tests uses microliters of reagents which can be a large cost savings over traditional flow instruments or manual testing.

Cost Effective

 

Low reagent consumption; only a few microliters of reagent are used for each sample.

Low running costs with nearly no consumables and low reagent and disposable costs.

Technical Specifications

  • Technology: Flow through, by peristaltic pump easily accessible

  • Sample/Reagent Preheating: Yes
  • Sample Capacity: 60 positions for samples, blank, standards and controls
  • Tests per Hour: 90 – Single reagent methods / 60 – Dual reagent methods
  • Dosing Syringe (Sample & reagents): 500 microliters syringe; resolution 0,096 microliters
  • Number of Reagent Positions: 30x35mL including diluents
  • Stock Solutions on Reagent Tray: Yes, working calibrants and QC diluted from stocks
  • Diluents Position: On refrigerated reagent tray,
  • Refrigerated Reagent Tray: Yes standard
  • Reagent Level Sensor: Yes
  • Number of Reaction Wells: 96 reaction microcuvettes with incubation temperature programmable +/- 0.1 °C.
  • Optical Path Length (mm): 50mm interchangeable with 15mm
  • Reaction Plate Temperature: 37° to 50°C adjustable +/-0.2°C
  • Incubator Type: Thermoelectric
  • Flow Cell Type: Optical glass
  • Main Detector: Colorimetric, temperature controlled; halogen lamp extended UV emission; automated zero settings; linearity up to 4.0 O.D.
  • Detector Technology: Interferential Filters
  • Number of Wavelengths: 9+blank
  • Reading Methods End Point: mono or bichromatic; End Point differential (Sample blank correction); Kinetic
  • Nitrate reduction methods:
  1. Green method w/o use of Cadmium or Hydrazine
  2. By Cd coil – Automated regeneration
  3. Hydrazine
  • Communication Software: Compatible with Windows XP, 7.0, 8.0, & 10
  • Sample Analysis: Work lists stored by the software with possibility to select independent list of parameters per each sample
  • Sample ID: Alphanumeric
  • Random Access to Samples, calib. Etc. : Yes
  • Sample Addition During Run: Yes
  • Sample & Reagent Blanking: Yes
  • Working Calibrant Dilution: Yes, from stock solution located in the refrigerated tray
  • Pre-Run Sample Dilution: Yes
  • Post-Run Sample Dilution: Yes, automated dilution and rerun of off scale samples
  • Multilevel QC & Closed Loop: Up to 5 QC levels, with closed loop control (QC check & pre programmed actions in case of QC and or Spike recovery failure)
  • QC Database and QC Chart: Yes
  • Automated Spike & Recovery Check: Yes
  • Automated Calibrations (Calibration Fits, Linear, Polynomial, etc.) : Yes, up to 16 calibrants
  • Calibration Correction: Yes, enable disable calibrants change calibration fit
  • Calibration QC Check & Calibration Repeat: Yes, if correlation lower than set value option for calibration repeat
  • Reagent Blank OD and Top Cal OD Check: Yes, if out of tolerance pre programmed actions
  • Results Correction: Yes, correction by dilution factor, moisture & weight
  • Import Work list & Export Results to LIMS: Yes
  • Multiple Diluents (soils analysis, phenols,
  • cyanide etc.): Yes
  • Size/Weight: 35cmx67cmx70cm(HxDxW)/45Kg
  • Power Supply: 220-240VAC +/- 5% or 110VAC – 50/60Hz Single phase with ground – Fuses 3.15Amp 230VAC, 6.3Amp 115VAC

Seawater Methods 50mm Flow Cell

Ammonia
Silicates
Total Nitrogen*
Nitrite
Ortho Phosphorous
Nitrate
Total Phosphorous*

*External sample pre-treatment required

Wastewater Methods 10mm Flow Cell

Alkalinity

Cyanide*

Sulfide

Aluminum

Fluoride*

Sulphate

Ammonia

Hardness

Total Kjeldahl Nitrogen*

Boron

Hydrazine N2H2

Total Kjeldahl Phosphorous*

Calcium

Iron

Total Nitrogen*

Chloride

Manganese

Total Phosphorous*

Chlorine Free

Nickel

Urea

Chlorine Total

Nitrite

Zinc

Chromium 6+

Ortho Phosphorous

Color

Phenolics C6H5OH*

Copper

Silicates

* External sample

pre-treatment required

Soils, Plants, Feeds and Fertilizers

AMMONIA

PHOSPHATE

CALCIUM

SILICATES

CHLORIDE

SULFATE

MAGNESIUM

TOTAL NITROGEN (TKN)*

NITRATE+NITRITE

TOTAL PHOSPHOROUS*

NITRITE

* External sample

pre-treatment required

Resources