EasyChem 200

EasyChem 200 Chemistry analyzer

Multi-Parameter Discrete Analyzer

The Systea Easychem 200 is a high throughput discrete analyzer designed to increase productivity and minimize costs while analyzing water, soil, and plant tissue.​

  • 60 Sample Capacity

  • Up to 200 tests per hour

  • Select Individual Parameters for Each Sample

  • Fully Automated

  • Export Results to Excel, LIMS or shared drive

  • Easy to Use – No scientific background required

Easy Operation

With the Easychem 200, Worklists can be programmed in minutes.

Simply enter the sample information and select which chemistries are to be performed.

Press play and the EasyChem 200 will run unattended for up to 720 tests.

Analysis Screen Showing Running Samples
EasyChem 200 Sample and Reagent Trays

Highly Automated

The Easychem 200 offers a highly automated solution that allows operators to program their daily worklist and then leave the instrument to run unattended as they perform other duties around the laboratory.

  • Start up and Shut Down
  • Calibration Curves
  • Pre or Post Dilutions
  • QC checks
  • Weight and Moisture Corrrections
  • Reagent and Instrument Monitoring
  • Data export

Multiple Reagent Positions

The Easychem 200 has up to 27 reagent positions. This allows for multiple chemistries to be run in parallel.

The reagent tray is refrigerated to extend the life of the reagents.

Each tests uses microliters of reagents which can be a large cost savings over traditional flow instruments or manual testing.

Closeup EasyChem 200 Sample and Reagent Trays
Calibration Screen
Automated Calibration

 

Calibration curves can be automatically generated from a known standard.

All calibration information is automatically saved for traceability and can be exported into reports for auditing purposes.

Cost Saving Wash Station

The Easychem 200’s integrated wash station improves throughput, reduces costs and waste and frees operator time.

After an analysis is performed, the reaction cuvette undergoes a five stage cleaning and QC check.

This eliminates the need for reusable cuvettes which can save thousands of dollars each year compared to other popular discrete analyzers.

Wash Station
Front view EasyChem 200

Technical Specifications

  • Sample Volume: 2-300µl, precision 1% at 10µl
  • Reagent Volume: 5-350 µl, precision < 1% at 250µl
  • Reaction Volume (Sample+ reagent volume, µL): 220-350
  • Automatic programmable pre or post dilution for each sample
  • Maximum test per hour: 200
  • Main Detector: Colorimetric, temperature controlled; halogen lamp extended UV emission; automated zero settings;accuracy +/- 1% from 0 to 2.5 O.D.; linearity better than 0.5%; noise <+/- 2m Abs. At 340 nm 2.5 O.D..
  • Samples Rack: Removable 60-position rack
  • Reagents Rack: Removable 27-position reagent rack, fits with 27 mL reagent bottles
  • Dosing Syringe: 368 microliters syringe with 0.14 l resolution; Zero automatic setting; Accuracy +/- 0.5% from 2 to 350 uL
  • Washing Station : 6 dispensing needles for washing solution, 6 sucking needles, 1 drying needle, 8 washing cycles for each cuvette
  • Reaction Cuvette: 80 BIONEX® cuvettes replaceable singularly, over 20.000 tests
  • Reading Methods: End point: mono o bichromatic; End Point differential (Sample blank correction); Kinetic
  • Dimensions: L x D x H: 60cm x 67cm x40cm
  • Weight: 32kg

Water Parameters

Alkalinity

Ammonia

Boron

Calcium

Chloride

Chlorine Free

Chlorine Total

Chromium IV

Color

Copper Diss

Cyanide*

Fluoride*

Hardness

Hydrazine

Iron Diss

Lead Diss

Magnesium

Monochloramine

Nickel Diss

Nitrate

NO2 + NO3

Nitrite

TN (persulfate)*

TN (TKN)*

Phenolics*

Phosphate

TP (TKP)*

TP (persulfate)*

Silica

Sulfide

Sulfate

Urea

Soil Parameters

Copper as Cu(I+II)- Acid-extractable

Nitrate as N-NO3 – CaCl2 extractable

Total Phosphorus as P – Kjeldahl

Iron as Fe(II+III)- Acid-extractable

Phosphorus as P-PO4 -CaCl2 extractable

Magnesium as Mg(II)

P (BSES-P) as P-PO4 -Acid extractable

Silicon as Si – CaCl2 extractable

Phosphorus as P-PO4–Olsen extractable

Silicon as Si – Acid extractable

Sulphate as SO42- – CaCl2 extractable

Phosphorus as P-PO4 – Sorption

Zinc as Zn(II)- Acid extractable

Calcium as Ca(II)

Total Kjeldahl Nitrogen as N-NH3

Phosphorus (Bray) as P-PO4 – Available

Colwell-extractable P as P-PO4

Total Protein Ammonia as N-NH3- CaCl2 extractable

Ammonia as N-NH3 – KCl extractable

Chloride as Cl- – Water extractable

Boron as B(III) -CaCl2 extractable

Nitrate as N-NO3 – KCl extractable

Nitrate as N-NO3 – Water extractable

Resources