Micromac-Smart

Micromac Smart

PORTABLE WATER ANALYZER FOR FAST, ACCURATE ON-SITE ANALYSIS

The Systea Micromac-Smart is a portable analyzer fully controlled by an integrated PC featuring an integrated color Touch Screen, designed for at site monitoring of all water resources.

RUGGED AND RELIABLE
The analyzer is mounted in a sturdy and
easy-to-transport plastic case including room
for reagents and other accessories. A
reagent frame holds all reagent bottles and
required solutions.

READY TO DEPLOY

User friendly and easy to learn, the Micromac-Smart is delivered from the factory fully tested and ready to use. Results are stored inside the analyzer memory and can be downloaded through USB port . Analyzer start up and operations have never been easier! Just turn on and insert the reagents; user-friendly software will guide the operator through all necessary steps. Reagent kits are available for all standard measurements.

HIGHLY AUTOMATED

The Micromac-Smart features fully automated calibration; simply use the calibration solution as specified in the manual and run. The new calibration factor is checked and accepted if verified to be within acceptance limits.

The analyzer identifies off scale samples and reanalyze the sample after automated dilution.

Micromac Smart Integrated Screen
Reagent Bottles

MULTIPLE MEASUREMENTS

The analyzer offers the option for continuous operational mode; the operator can perform sequential measurements several times
on the same sample or just leave the analyzer running while the sample flows.

The analyzer can be delivered ready for multiple measurements (MP versions) on the same sample; several set ups are available as standard.

Technical Specifications

MEASURING PRINCIPLE:

  • COD UV: SAC at 254nm turbidity correction at 550nm as per DIN348404-3; COD correlation against known calibrant
  • BOD FLUO: Fluorimetric measurement (tryptophan like) excitation at 280nm, emission at 360nm; BOD correlation by Tryptophan calibrant to be adjusted and/or performed on site
  • Turbidity: measurement at 850nm as per ISO 7027, option: correlation with TSS to be performed on site
  • Nitrate UV: direct reading at 220 nm, correction at 275 nm Colorimetric methods: as per method description


STANDARD RANGES:

  • Ammonia: 0-0.3/0.5/1.0/2.0/5.0/10.0 mg/L N-NH3
  • Nitrate+Nitrite Colorimetric: 0.3/0.5/1.0/2.0/5.0/10.0 mg/L N-NOx
  • Nitrate UV: 0-10/120/30/50 mg/L N-NO3
  • Nitrite: 0-0.05/0.1/0.2/0.3/0.5/1.0 mg/L N-NO2
  • Phosphate: 0-0.3/0.5/1.0/2.0/5.0 mg/L P-PO4
  • TN Colorimetric: 0-2.0/5.0/10.0/20.0 mg/L N
  • TN UV: 0-10/20/30/50 mg/L N
  • TP: 0-1.0/2.0/5.0/10.0 mg/L P
  • COD: 0-50/100/200/1000/2000/3000 mg/L
  • BOD: 0-20/50/100/500 mg/L
  • Turbidity: 0-20/50/100/500/1000 NTU


MEASUREMENT TYPE:

  • Batch
  • MP version batch
  • sequential


MEASURING FREQUENCY

  • Single measurement
  • MP4 measurement
  • continuous programmable


MEASURING TIME

  • MP4 Nutrients: 40/50 minutes, depending on ranges, for the complete set of 4 methods
  • TN & TP: 40/60 minutes depending on ranges
  • COD: 7-10 min / BOD: 7-10 min / Turbidity: 7-10 min; depending on range and sample temperature, for combined versions 10-15 min


COMMUNICATIONS PORT:
USB


ALARM MESSAGES:
On 8″ color touch screen and on results buffer


REAGENTS:
Reagent kit available on request


ENVIRONMENTAL TEMP.
10-35 °C


STANDARD PROTECTION:
IP 65 with closed case


HARDWARE:
PC104 standard microcontroller, integrated 8″ color touch screen


POWER SUPPLY:
12 Vcc; external power supply from 110/220 Vac to 12 Vcc included in the scope of delivery


ABSORPTION:
4W stand by, 10 W analysis
WEIGHT: 7.7 Kg without reagents


DIMENSION:
180x460x360 mm (H x W x D)

Resources