Cadmium Reduction Coil

Cadmium Coils and the Analysis of Nitrate

This post is designed to offer assistance to users of cadmium coils in the analysis of Nitrate. Since the use of the cadmium coil is fairly complicated and because there are many possible applications, we want to discuss the different sizes that are available as well as the advantages of the various sizes. Cadmium coils [...]

2017-09-27T12:08:18-07:00

Cadmium Coils and Surfactant Buildup

Old Surfactant Solution Causes Problems in Cadmium Reduction Coils In our earlier blog posts we have discussed many reasons for possible loss of cadmium coil reduction efficiency. Along with metal contamination, nitrate contamination and gas contamination, we have also seen old surfactant solution cause problems in cadmium reduction coils. Because of the unstable nature of [...]

2017-09-27T12:08:18-07:00

OTCR Cadmium Coil Common Sizes

Getting the Correct OTCR Cadmium Coil for Your Flow Analyzer In our cadmium coil blog series, we wanted to address the difference between our 12 inch and 24 inch OTCR (Open Tubular Cadmium Reaction) cadmium coils. The 12-inch coil was originally designed to be used on RFA instruments that used a slower pump speed and [...]

2017-09-27T12:08:18-07:00

Metal Contamination Reduces Cadmium Coil Efficiency

Last week, we discussed the loss of reduction efficiency in cadmium coils caused by nitrate contamination in ammonium chloride. This week we are examining metal contamination and cadmium coil efficiency. This type of contamination occurs in the sulfanilamide solution. Of course, sulfanilamide solution contains N-naphthylethylenediamine dihydrochloride which serves to bind heavy metals. If metal exists [...]

2017-09-27T12:08:19-07:00

Nitrate Contamination Reduces Cadmium Coil Efficiency

Nitrate Contamination: A very real and very well documented effect in various laboratories is the loss of reduction efficiency in cadmium coils caused by nitrate contamination in the ammonium chloride. Nitrate contamination will cause a steady continuous reaction in a cadmium reduction coil during a run. Depending on the level of contamination, this condition can [...]

2015-03-23T09:25:48-07:00

Segmented Flow Analysis and the Cadmium Coil

Two things to consider when using a cadmium coil in a segmented flow analysis system: Pure gas & checking the system for leaks. Pure gas is vital when it comes to the cadmium coil, any impurities in the gas or leaks in the SFA system itself will significantly reduce a cadmium coil's reductive efficiency. In [...]

2015-03-24T08:37:49-07:00

Everything You Wanted to Know About the Cadmium Reduction Coil

An Overview of Caring For and Using a Cadmium Reduction Coil in the Determination of Nitrate. Over the years, we've fielded a lot of questions from clients about how to operate and get the most out of their cadmium coils. Cadmium coils are fairly complicated and there are definitely areas for problems to occur. Sometimes [...]

2017-09-27T12:08:19-07:00